  • Modular UPS 6-36kVA
    ERMS Modular UPS 6-36kVA

    19’’ shelf Truly Modular UPS Full UPS functioned UPS Module System Capicity: 6kVA - 36kVA , 6kVA UPS Module High Frequency MODULAR UPS Modular,hot-swappable, field-replaceable Monitor, UPS module. Embedded modular power protection with ultra high availability and efficiency for Small Date Center.

  • Modular UPS 10-100kVA
    CMS Modular UPS 10-100kVA

    System Capicity: 10kVA - 100kVA Module Capicity: 10kVA 3/3, 3/1, 1/3, 1/1; 50/60Hz; BOTTOM/TOP feed High Frequency MODULAR UPS Choice of UPS module result in rational redundancy. Modular,hot-swappable, field-replaceable STS, monitor, UPS module. Scalable from 10KVA to 100KVA. Parallel-capable up to 400KVA.

  • UPS System
    Data Center And Facility UPS

    Reduandant, scalable arichitecture 96% efficency, highest reliability data centre and facility UPS protects the critical applications System Capicity: 50kVA - 3200kVA Module Capicity: 50kVA 3/3, 3/1, 1/3, 1/1; 50/60Hz; BOTTOM/TOP feed High Frequency MODULAR UPS Modular,hot-swappable, field-replaceable STS, monitor, UPS module Scalable from 50KVA to 800KVA. Parallel-capable up to 3200KVA

  • Sicon Modular UPS CMS-150/25
    Sicon Modular Online UPS Power CMS-150/25

    Power range: 25KVA-150KVA Spec: 220/380VAC, 50/60Hz, 3-phase Tech: high frequency modular UPS, rational redundancy. Modular, hot-swappable, field-replaceable STS, monitor, UPS module. Scalable from 25KVA to 150KVA. Parallel-capable up to 600KVA.

  • Sicon CMS Modular UPS 120-640KVA
    CMS Modular UPS 120-640KVA

    System Capacity: 120-640 KVA Module Capacity: 40KVA 3/3, 3/1, 1/3, 1/1; 50/60Hz; BOTTOM/TOP feed High Frequency MODULAR UPS Choice of UPS module result in rational redundancy Modular, hot-swappable, field-replaceable STS, monitor, UPS module. Scalable from 120 KVA to 640 KVA.

  • 3 Phase Online UPS 10-50kVA - SICON
    3 Phase Online UPS 10-50kVA

    True Modular UPS Max Power: 50kVA UPS Chassis: 50kVA (600*800*1200mm) UPS module: 10kVA (2U) 3/3// 380Vac 400Vac 415Vac Hot-swappable, field-replaceable Bypass module, Display module, UPS module 3 Phase UPS power protection, solving today’s energy challenges while setting the standard for quality and innovation with fully integrated solutions for enterprise-wide networks, data centers, mission-critical systems, and industrial/manufacturing processes.

  • 3 Phase Online UPS 10-100kVA - SICON
    3 Phase Online UPS 10-100kVA

    True Modular UPS Max Power: 100kVA UPS Chassis: 100kVA (600*800*1600mm) UPS module: 10kVA (2U) 3/3// 380Vac 400Vac 415Vac Hot-swappable, field-replaceable Bypass module, Display module, UPS module 3 Phase UPS power protection, solving today’s energy challenges while setting the standard for quality and innovation with fully integrated solutions for enterprise-wide networks, data centers, mission-critical systems, and industrial/manufacturing processes.

  • 3 Phase Online UPS 25-150kVA - SICON
    3 Phase Online UPS 25-150kVA

    True Modular UPS Max Power: 150kVA UPS Chassis: 150kVA (600*800*1600mm) UPS module: 25kVA (3U) 3/3// 380Vac 400Vac 415Vac Hot-swappable, field-replaceable Bypass module, Display module, UPS module 3 Phase UPS power protection, solving today’s energy challenges while setting the standard for quality and innovation with fully integrated solutions for enterprise-wide networks, data centers, mission-critical systems, and industrial/manufacturing processes.