Overview

Range International Information Group data center occupies 32,866.24 building area. According to Range's actual situation and high requirements of cloud computing, the integrated data center works as the pivot of communications and IT information system, and covers all aspects including infrastructure, technology and system architecture, application and data, service and IT process, organization and operation, enterprise and information strategy. Therefore, the infrastructure, network, computing resources, management system planning, and design and construction of the data center, must comply with the date center's feature, developing trend, and performance.

M4 Module_Range DATA CENTER

Covered area

7568.12 sq.m.

Statistics of rental and sales equipment cabinets

951sets IT cabinets + 650sq.m. reserved space

Building height

28m

Number of Plies

4 Plies over ground, 1 Ply underground

Seismic Fortification Intensity

8 Degree

Construction Type

Steel structure over ground, Reinforced concrete structure underground.

Fire resistance rating

Grade 1

Function Division

1F(Infrastructure)

2-4F(Data room area)

2-4F set equipment pipe sandwich.

The challenge

Create a highly efficient data centre that would be simple to upgrade and able to facilitate mixed densities to accommodate different customer requirements. The facility needed to be scalable for future growth without disruption to existing clients, as well as robust and resilient to protect customersdata and ensure business continuity. Cost efficiency was also important and, as part of this, the whitespace had to be maximised.

The solution

SICON applies modular UPS devices operating in dual-bus redundancy mode, with every in N+2 mode and the system in 2N mode, to meet power supply redundancy requirements and provide reliable power protection for equipment operation.

21 sets of CMS 480kVA modular UPS + 3 sets of CMS 300kVA modular UPS Power Supply(Uninterruptible Power System)

Detail:

3 sets of CMS 300kVA modular UPS, 1st Floor, for air condition

8 sets of CMS 480kVA modular UPS, 2nd Floor, for IT facilities and air condition|TIER IV

8 sets of CMS 480kVA modular UPS, 3rd Floor, for IT facilities and air condition|TIER III

8 sets of CMS 480kVA modular UPS, 4th Floor, for IT facilities and air condition|TIER IV


The Benefits:

High performance and extensibility;

Safe, stable, and saving;

Energy-saving, environment-friendly, and emission-reducing.