How much UPS capacity do you need?
- 2020-05-18 16:22:50
- admin
You can estimate your UPS capacity requirement by totaling the requirements of all the equipment you plan to connect to the online UPS . You should refer to the equipment manufacturer's documentation to find the wattage. If you can't find any printed or online documentation, refer to the equipment nameplate. If your equipment lists its power requirements in amps, multiply the number of amps by the...
-
Three Phase Power
- 2019-06-18 15:55:49
- admin
As well being the most efficient way to distribute power over long distances, three-phase power also enables industrial equipment to operate more efficiently. Three-phase power is characterised by three single-phase waves that are offset in their phase angle by 120 degrees, or one third of the sine wave period (see Figure 1). Three-phase voltage can be measured from each phase to neutral or from o...
-
What kinds of batteries are used in a UPS?
- 2019-06-18 15:56:14
- admin
Most commercially available uninterruptible power supply (UPS system) use sealed lead-acid batteries that are water-and maintenance-free. The energy is generated by chemical reactions in a paste-like electrolyte. For most consumers, these batteries are not only easy to use and maintain but also simple to replace when necessary. Sicon Video&Sicon Online Showroom Contact Sicon Team Tel: 86-311-8...
-
Reduce the loss of power risks,right now!
- 2019-06-18 15:57:06
- admin
If you have witnessed in the past flickering lights in your home or office, computer freezing up or restarting, then you may be suffering a power supply problem. The IT equipment storing data is extremely sensitive and will not tolerate loss of power for more than a few milliseconds. It is also at risk from power anomalies such as over-voltages, transients, sags and spikes arising from the power&n...
-
UPS form factors
- 2019-06-18 15:58:02
- admin
Because UPS are used for many different applications - ranging from desktop systems to large data center ,they come in a wide variety of form factors. 1. Desktop and tower UPS The Sicon DSP11 series tower UPS fits under a desk or in a network cabinet 2. Rack mount UPS The Sicon DSP11 rack mount UPS occupies only 2U of rack space, can be embedded in 19 inch standa...
-
Three ways to reduce your maintenance costs for the UPS system
- 2019-06-18 16:18:44
- admin
While maintenance and repairs are an expected and inevitable part of facility management, the costs attached to them can still be a wildcard.You may try to do the following to reduce the maintenance cost. ★3-Phase UPS Installation If you are considering a three phase UPS , consider units with low (≤5%) THDI. Low THDi saves money by reducing or eliminating the need to over-size generators, breakers...
-
Tips to Save Energy in the Data Center (1)
- 2019-06-18 16:19:31
- admin
If you manage a data center , or engineer the architecture for clients who do, you know how critical to save energy have become. High-density computing environments can be a huge drain on operating budgets for several reasons:1) expanding power demands, 2) increasing power costs, and 3) excessive heat. It's a challenge to conserve energy while supporting these growing loads - without bringing unwa...
-
Factors affecting battery life
- 2019-06-18 16:21:19
- admin
All UPS(uninterruptible power supply) batteries have a limited service life, regardless of how or where the UPS is deployed.While determining battery life can be tricky, there are five primary factors that affect a battery’s overall lifespan. 1. Ambient temperature Because the rated capacity of a battery is based on an ambient temperature of 25°C, any variation from this can affect performance and...